Skip navigation

Latest News

Fire Code Friday: Locks & Latches

March 15, 2024

TGIFire Code Friday! Let’s review some lock and latch code (NFPA 80 6.4.4): *Locks with interconnected deadbolts which are retracted when the latch bolt is retracted are permitted. *Automatic devices are permitted but must be activated by the fire protection system and become unlatched upon activation. *The latch throw minimum must be shown on the […]

Read full story >>

Tech Talk: Cameron

March 11, 2024

This month, we chat with Cameron. He has been a technician with FedLock for about 1 year.  Q: What is your favorite type of lock to replace/repair?A: Yale mortise locks are a well made, quality lock that I enjoy working with.   Q: What advice would you give about home locks and why?A: Use reputable hardware brands, not a discount knock-off […]

Read full story >>

Answering the Call

March 5, 2024

Did you know that we work on callboxes and entry systems? We do! We can help with a variety of issues: programming, troubleshooting, or replacement of hardware. We can also install doorbells with cameras and remote release if the entrance isn’t in the line of sight of the concierge or receptionist. Contact us with questions!

Read full story >>

Open callbox, showing the electronics and wires

Fire Code Friday: Stair to Roof Access

January 26, 2024

TGIFire Code Friday! 🔥 Have you seen the movie “The Hangover”? You may remember the bachelor gets trapped on a roof for a weekend. Well, thanks to NFPA 101, that should never happen in real life! Section 7.2.1.5.7 is all about stairwells and states if a stair enclosure allows access to the roof of the […]

Read full story >>

Fire Code Friday: Continuous Hinges

January 19, 2024

TGIFire Code Friday ! Per NFPA 80.6.4, continuous hinges must be within 1″ of the door height. On an existing door, this installation may require filling holes from the standard hinges but will still meet code. A continuous hinge prevents the door from sagging, which not only helps with everyday functionality, but can correct the clearance […]

Read full story >>

Fire Code Friday: Standard Hinges

January 12, 2024

TGIFire Code Friday!  NFPA 80 6.4 requires that (2) hinges be used on doors up to 60 inches in height. One additional hinge should be used per each additional 30 inches (or fraction) of door height. If you have any tall fire-rated doors, this may require (4) or more hinges.

Read full story >>

Fire Code Friday: Closing Device

January 5, 2024

TGIF, it’s Fire Code Friday ! To help contain potential fires, a closing device is required on every fire door, adjusted to ensure positive latching on each door operation (NFPA 80 – 6.4). If you have doors that don’t close or latch properly, contact us ASAP for service.

Read full story >>

Fire Code Friday: Hardware Classifications

December 22, 2023

TGIF, it’s Fire Code Friday! Per NFPA 80.4.6, there are multiple classifications of hardware: *Builders’ hardware includes hinges, locks and latches, bolts and closers. *Fire exit hardware is an exit device labeled for both panic and fire protection. *Fire door hardware includes surface-mounted strap hinges, surface-applied latches and closing devices.

Read full story >>

Tech Talk: Silas

December 19, 2023

This month, we head into the office to chat with one of our communications team members, Silas. He has worked in various industries, and has been with FedLock for about 1.5 years.  Q: What is the most fun or unique thing you’ve learned about security hardware?A: It’s hard to pinpoint one thing exactly because I am still learning. […]

Read full story >>

TGIFire Code Friday: Panic Bars

December 15, 2023

When installing or repairing exit devices, keep in mind these code considerations: -The actuating portion of the device must be at least half the width of the door. -Panic hardware must be mounted 34-48 inches above the floor. -NO additional locking device (deadlock, padlock, chain, etc) may be installed nor can you have any device […]